ALARM PANELS
NESS X SERIES FEATURES
56 USER CODES
Each user code can be assigned to AREA1, AREA2, CODE ONLY ARMING, ARM ONLY, KEYPAD CODE, RADIO CODE, ACCESS CODE READER1, 2 OR 3.
ACCESS CONTROL FUNCTIONS
New access control features with flexible programming options. Connect up to 3 access control proximity Weigand readers.
Use the access control option to open electric door locks or arm/disarm the panel or both!
ARM/DISARM USING PROX CARDS
The access control feature allows up to 55 individual users to arm and disarm using proximity access cards. Prox cards can even be used to operate electric doors locks for secure hands free entry.
MODULAR HOUSING
The new EB04 enhanced housing is tough and roomy with a removable lid for easy access. The housing is generously fitted with multiple standoff positions, cable tie loops, cable/conduit entry points and unique slide-in carriers for the new X Series accessory boards.
ACCESSORIES
A new range of X Series slide-in accessory boards includes a four relay board, a reader interface and the new X Series Output Expander for both the D8x and D16x panels.
MAIN SOFTWARE FEATURES
- 56 user codes can be assigned to 3 to 6 digits PIN codes with keypad options including Area assignment, Arm Only options, Code Only arming and much more.
- Two button arming feature.
- Fire Alarm feature with different siren tones.
- Input to output mapping.
- Programmable 2 area partitioning with overlapping of zones in areas allowed.
- Programmable sensitivity for vibration sensors - zone by zone basis.
- Programmable Long Response times for zones (1sec or 3sec).
- Monitor mode and Day Zone feature.
- Temporary Day Zone feature for Day Zone setup “On the fly”.
- Single or double trigger option on a zone-by-zone basis.
- Supports up to 55 Radio Keys.
- Access Control feature with provision for up to 3 Readers.
- Supports up to 55 Proximity Access Cards or Fobs.
- Uses NessComms up/download software package.
- Secure DTMF remote arming/disarming capabilities.
- Programmable siren/reset lockout.
- 30 event memory from keypad.
- Expanded event memory can be accessed by NessComms™.
- Disable unused zones feature.
- Siren chirp/strobe flash on radio key arming with ‘quiet chirp’ option.
- Standard defaults to suit most applications.
- Quiet chirps on Arm/Disarm option.
- and much more...
MAIN HARDWARE FEATURES
- 8 or 16 Fully programmable zones.
- D16x has 16 physical zone inputs or Zone Split option.
- 2 additional 24hr inputs.
- End Of Line supervision 2K2 or 3K3 programmable.
- D8x supports up to 3 remote LED or LCD Keypads.
- D16x supports up to 3 remote LCD Keypads.
- Plug-in Radio Interface supports any Ness radio device.
- New Serial port for connection to future accessories.
- Fast direct connect upload/download via the Serial port.
- Reader port connects up to 3 addressable access control readers.
- Output Expander option for both D8x and D16x.
- New LISTEN pins allow the installer to diagnose dialler tones on site.
- True dynamic battery test hourly.
- 4 programmable auxiliary outputs.
- Programmable REX inputs for access control.
- Automatic resetting fuses on all outputs.
- Optional latching or momentary keyswitch arming option.
- Option for an extension sonalert to mimic all keypad beeps.
- New attractive and versatile housing with installer friendly design.
- Plug in accessory boards available.
- Complies with all relevant Australian and CE standards.
- and much more...
Click here to read the brochure [Size: 429 KB]
Click here to read the article [Size: 178 KB]
To see the above files you need Adobe PDF Reader.
Click here to download it. [Size: 27.4 MB]
NESS D8, 8 ZONE DIALLER CONTROL PANEL WITH LED KEYPAD
The Ness D8 is a powerful and fully featured 8 zone alarm control panel with built-in digital dialler.
The most modern hardware and software techniques have been employed to make the D8 totally reliable, secure and excellent value for money.
Supplied complete with the very attractive and user friendly D8 backlit LED keypad as well as a plug pack and battery.
- Includes LED or LCD keypad, plug pack and battery.
- 8 fully programmable zones.
- 1 Additional 24 hour input.
- Total zone flexibility using any of 16 different zone applications.
- Inputs can be programmed to activate different outputs (input to output mapping).
- End of line supervision for cable tampering when system is on.
- 3 area partitioning.
- Overlapping of zones in areas allowed.
- Adjustable sensitivity for vibration sensors on a zone by zone basis.
- Monitor mode.
- Day zone feature.
- Single or double trigger option on a zone by zone basis.
D8 LED Control Panel
Part No: 100-191
D8 LCD Control Panel
Part No: 100-688
Ness D8 more information
NESS R8 RADIO CONTROL PANEL
FULLY WIRELESS, TOTALLY SELF-CONTAINED
The Ness R8 is a new and unique fully self-contained radio control panel.
The panel has a built-in keypad for programming and user operation, a built-in piezo siren, built-in LCD display, built-in radio receiver, built-in battery backup and built-in dialler.
The R8 supports up to 8 Ness radio PIRs and up to 14 Ness Radio Keys. All Ness supervised and encrypted radio devices are supported. There is even a Doorbell feature with selectable tunes when used with the Ness Radio Doorbell transmitter.
In addition to the 8 radio zones, the R8 has 1 hardwired zone and 1 hardwired tamper input.
- Onboard lcd display
- Onboard backlit keypad
- Onboard radio receiver
- Onboard dialler
- Onboard piezo siren
- Onboard battery backup
- Doorbell feature
- Remote arm/disarm by telephone
- Remote programming by computer
- Full 48hrs battery backup (inc. 1 full alarm)
- Fully compatible with all Ness radio devices
Part No: 100-690
Ness R8 more information